V60 Curtain Wall System (Patented)
Scroll down for layouts and test results.
Components

Head & Sill In Vertical Section |

Single L-Cut Jamb Condition

Double L-Cut Jamb Condition
|
Back to Top
Layout

Horizontal Sectional Layout

Corner Condition
Back to Top
Test Results
The V60 System with LINIT Channel Glass has been tested and certified as passing:
- Static air infiltration: ASTM E283 - results: .01 cfm @ 6.24 psf
- Structural deflection: ASTM E330 - results: < L/300 @ 30 psf (pg. 10)
- Static water infiltration: ASTM E331 - results: no leakage @ 15 psf
- Dynamic pressure water infiltration: AAMA 501.1 - results: no leakage @ 15 psf
- Interstory drift: AAMA 501.4 - results: category III performance @ +/- 3.00" displacement from 0.
- Condensation Resistance Factor, in accordance with AAMA 1503-98 is 0.57
- U-Value of the assembled system in accordance with AAMA 1503-98 is 0.50
- Acoustical test performance in accordance with ASTM E90, ASTM E413, and ASTM E1332: STC - 40, OITC - 40
Back to Top
Note: Information and configurations shown on this sketch are for concept only. Contact Bendheim Wall Systems, Inc. for details.